AC/DC Voltage Measurements
|
Accuracy
|
Range: 600.0 V
Resolution: 0.1 V
50 Hz to 400 Hz ± (% of Rdg + Digits): ±(2 % + 3)
|
Input Impedance
|
3 MΩ (nominal), < 100 pF
|
Common mode rejection ratio (1 kΩ unbalanced)
|
> 60 dB at dc, 50 or 60 Hz
|
Overload Protection
|
600 V rms or dc
|
Earth bond resistance measurement
|
Range/Resolution
|
20.00 Ω 0.01 Ω
200.0 Ω 0.1 Ω
2000 Ω 1.0 Ω
20.00 kΩ 0.01 kΩ
|
Accuracy
|
±(1.5% + 3)
|
Overload Protection
|
2 V rms or dc
|
Open Circuit Test Voltage
|
> 4.0 V, < 8 V
|
Short circuit current
|
> 200.0 mA
|
Insulation Specifications
|
Measurement Range
|
0.01 MΩ to 2000 MΩ
|
Test voltages
|
500 V, 1000V
|
Test Voltage Accuracy
|
+ 20 %, - 0 %
|
Short circuit current
|
1 mA nominal
|
Auto Discharge
|
Discharge time < 0.5 second for C = 1 µF or less
|
Live circuit indicator
|
Inhibit test if terminal voltage > 30 V prior to initialization of test
|
Maximum Capacitive Load
|
Operable with up to 1 µF load
|
Measure Accuracy
|
50 V: ±(3 % + 5)
100 V: ±(3 % + 5)
250 V: ±(1.5 % + 5)
500 V: ±(1.5 % + 5)
1000 V: ±(1.5 % + 5) to 2000 MΩ, ±(10 % + 3) above 2000 MΩ
|
General Specifications
|
Maximum voltage applied to any terminal:
|
600 V ac rms or dc
|
Storage temperature
|
-40 °C to 60 °C (-40 °F to 140 °F)
|
Operating temperature
|
-20 °C to 55 °C (-4 °F to 131 °F)
|
Temperature Coefficient
|
0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F)
|
Relative Humidity
|
0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F)
0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F)
0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F)
|
Vibration
|
Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
|
Shock
|
1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)
|
Electromagnetic compatibility
|
In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997)
|
Safety
|
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)
|
Certifications
|
CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition
|
Batteries
|
Four AA batteries (NEDA 15A or IEC LR6)
|
Battery life
|
Insulation test use: Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Resistance measurements: Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.
|
Size
|
5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L)
|
Weight
|
550 g (1.2 lb)
|
IP Rating
|
IP40
|
Altitude
|
Operating: 2000 m CAT IV 600 V, 3000 m CAT III 600 V
Non-operating (storage): 12,000 m
|
Over-range capability
|
110% of range
|
Included accessories
|
TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe
|
AC/DC Voltage Measurements
|
Accuracy
|
Range: 600.0 V
Resolution: 0.1 V
50 Hz to 400 Hz ± (% of Rdg + Digits): ±(2 % + 3)
|
Input Impedance
|
3 MΩ (nominal), < 100 pF
|
Common mode rejection ratio (1 kΩ unbalanced)
|
> 60 dB at dc, 50 or 60 Hz
|
Overload Protection
|
600 V rms or dc
|
Earth bond resistance measurement
|
Range/Resolution
|
20.00 Ω 0.01 Ω
200.0 Ω 0.1 Ω
2000 Ω 1.0 Ω
20.00 kΩ 0.01 kΩ
|
Accuracy
|
±(1.5% + 3)
|
Overload Protection
|
2 V rms or dc
|
Open Circuit Test Voltage
|
> 4.0 V, < 8 V
|
Short circuit current
|
> 200.0 mA
|
Insulation Specifications
|
Measurement Range
|
0.01 MΩ to 2000 MΩ
|
Test voltages
|
500 V, 1000V
|
Test Voltage Accuracy
|
+ 20 %, - 0 %
|
Short circuit current
|
1 mA nominal
|
Auto Discharge
|
Discharge time < 0.5 second for C = 1 µF or less
|
Live circuit indicator
|
Inhibit test if terminal voltage > 30 V prior to initialization of test
|
Maximum Capacitive Load
|
Operable with up to 1 µF load
|
Measure Accuracy
|
50 V: ±(3 % + 5)
100 V: ±(3 % + 5)
250 V: ±(1.5 % + 5)
500 V: ±(1.5 % + 5)
1000 V: ±(1.5 % + 5) to 2000 MΩ, ±(10 % + 3) above 2000 MΩ
|
General Specifications
|
Maximum voltage applied to any terminal:
|
600 V ac rms or dc
|
Storage temperature
|
-40 °C to 60 °C (-40 °F to 140 °F)
|
Operating temperature
|
-20 °C to 55 °C (-4 °F to 131 °F)
|
Temperature Coefficient
|
0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F)
|
Relative Humidity
|
0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F)
0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F)
0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F)
|
Vibration
|
Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
|
Shock
|
1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)
|
Electromagnetic compatibility
|
In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997)
|
Safety
|
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)
|
Certifications
|
CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition
|
Batteries
|
Four AA batteries (NEDA 15A or IEC LR6)
|
Battery life
|
Insulation test use: Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Resistance measurements: Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.
|
Size
|
5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L)
|
Weight
|
550 g (1.2 lb)
|
IP Rating
|
IP40
|
Altitude
|
Operating: 2000 m CAT IV 600 V, 3000 m CAT III 600 V
Non-operating (storage): 12,000 m
|
Over-range capability
|
110% of range
|
Included accessories
|
TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe
|