Ampe kìm đo dòng Sonel CMP-1006
AC/DC current measurement (TRUE RMS)
Range Resolution Accuracy(DC) Accuracy(AC)
0...659,9A 0,1A ±(2,5% m.v. +5 digits) ±(2,5 m.v. % + 8 digits) for f=50...60Hz
660...1000A 1A ±(2,8 m.v. digits % +8 ) ±(2,8 m.v. % + 8 digits) for f=50...60Hz
DC voltage measurement
Range Resolution Accuracy
0...6,599V 0,001V ±(1,5 m.v. digits % + 3 )
6,60...65,99V 0,01V ±(1,5 m.v. digits % + 3 )
66,0...600,0V 0,1V ±(1,5 m.v. digits % + 3 )
AC voltage measurement (TRUE RMS)
Range Resolution Accuracy
0...6,599V 0,001V ±(1,8 m.v. % + 5 digits) for f=50...60Hz
6,60...65,99V 0,01V ±(1,8 m.v. % + 5 digits) for f=50...60Hz
66,0...600,0V 0,1V ±(1,8 m.v. % + 5 digits) for f=50...60Hz
Resistance measurement: Ampe kìm đo dòng Sonel CMP-1006
Range Resolution Accuracy
0,0...659,9 Ω 0,1Ω ±(1.2% m.v. + 2 digits)sensitivity: 30...5kHz:10Vrms
min.5kHz...15kHz:40Vrms min.for 20%...80% duty cycle
0,660...6,599k Ω 0,001kΩ ±(1.2% m.v. + 2 digits)sensitivity: 30...5kHz:10Vrms
min.5kHz...15kHz:40Vrms min.for 20%...80% duty cycle
6,60...65,99k Ω 0,01kΩ ±(1.2% m.v. + 2 digits)sensitivity: 30...5kHz:10Vrms
min.5kHz...15kHz:40Vrms min.for 20%...80% duty cycle
66,0...659,9k Ω 0,1kΩ ±(1.2% m.v. + 2 digits)sensitivity: 30...5kHz:10Vrms
min.5kHz...15kHz:40Vrms min.for 20%...80% duty cycle
0,660...6,599M Ω 0,001MΩ ±(1.2% m.v. + 2 digits)sensitivity: 30...5kHz:10Vrms
min.5kHz...15kHz:40Vrms min.for 20%...80% duty cycle
6,60...66,00M Ω 0,01MΩ ±(1.2% m.v. + 2 digits)sensitivity: 30...5kHz:10Vrms
min.5kHz...15kHz:40Vrms min.for 20%...80% duty cycle
Temperature measurement
Range Resolution Accuracy
-20...760 C ° 1 C ° ±(3,0 m.v. % + 5°C)
-4...1400 F ° 1°F ±(3,0 m.v. % + 9°C)
Duty cycle measurement
Range Accuracy Resolution
10,0...94,9% 0,1% ±(1,2% + 2 ) m.v. digits
Electric security:
- measurement category CAT III 600V acc. to EN 61010-1:2004
- protection class acc. to EN 60529 IP40
Other technical data:
- power supply 9V battery type 6LR61
- display 6600 counts, backlit LCD
- continuity test threshold 40Ω ; test current < 0,5mA
- diode test test current of 0,3mA, typical
open circuit voltage < 3V DC, typical
- low battery indication BAT displayed
- over range indication 0L displayed
- sampling rate 2 times per second
- INRUSH integration time 100ms
- temperature sensor type K thermocouple
- input impedance 10MΩ (V DC and V AC)
- AC bandwidth 50...400Hz (A AC and V AC)
- auto power OFF approx. 25 min.
- dimensions 229 x 80 x 49 mm
- weight 303 g
- accordance with following standards EN 61010-1:2004
EN 61010-2-032
- quality standard ISO 9001
Rated operational conditions:
- s internal clamp diametes d1=36mm/d2=52mm
- operating temperature +5...+50°C
- storage temperature -20...+60°C
- operating humidity max 80% up to 31°C
decreasing linearly to 50% at 40°C
- storage humidity <80%
- operating altitude max 2000 m
internal clamp diameter