Ampe kìm đo dòng CMP_400, CMP-401
	CMP-400 i CMP-401
	DC current measurement (CMP-401 only) and AC current.
	AC/DC voltage measurement up to 600V.
	Resistance measurement and continuity test:
	- continuity test with acoustic signalling (beeper) for resistance below 50Ω.
	Temperature measurement (Fahrenheit and Celsius units).
	Frequency measurement.
	Capacitance measurement (CMP-401 only).
	Diode test.
	Additionally:
	- safe, insulated measuring clamps,
	- double molded housing,
	- autoranging/manual range selection,
	„DATA HOLD” function, for holding measured values,
	- backlit LCD,
	- „REL” function,
	- over range indication,
	- „AUTO-OFF” function.
	Temperature measurement
	Range                               Accuracy *
	-20,0 ... 760,0 °C              ±(3% m.v. + 5°C)
	-4,0 ... 1400 °F                  ±(3% m.v. + 9°F)
	*) probe (K type) accuracy not included
	Frequency measurement
	 
	Range                                             Accuracy
	10Hz ... 10kHz                          ±(1,5% m.v. + 2 digits)
	sensitivity: 100V(<50Hz), 50V(50…400Hz); 15V(401Hz…10kHz)
	AC current measurement
	Range                          Resolution                Accuracy                          Accuracy
	                                                                        CMP-401                          CMP-400 
	 4,000 A                      0,001 A                     ±(2,5% m.v. + 12 digits)     no range
	40,00 A                       0,01 A                        ±(2,5% m.v. + 8 digits)       ±(2,5% m.v. + 8 digits)                   
	400,0 A                       0,1 A                          ±(2,8% m.v. + 8 digits)        ±(2,8% m.v. + 5 digits)
	·         frequency range: 50...60Hz.                                   
	DC current measurement (CMP-401 only)
	Range                    Resolution                Accuracy
	40,00 A                0,01 A                       ±(2,5% m.v. + 5 digits)
	400,0 A                0,1 A                          ±(2,8% m.v. + 5 digits)
	AC voltage measurement
	Range                               Resolution                       Accuracy                     Accuracy
	                                                                                  CMP-400                         CMP-401
	400,0 mV                       0,1 mV                              no range                      ±(1,5% m.v. + 30 digits)                      
	4,000 V                           0,001 V                      ±(1,8% w.m. + 8 digits)   ±(1,5% m.v. + 5 digits)
	40,00 V                          0,01 V                          ±(1,8% w.m. + 8 digits)   ±(1,5% m.v. + 5 digits)                            
	400,0 V                          0,1 V                             ±(1,8% w.m. + 8 digits)   ±(1,5% m.v. + 5 digits)
	600,0 V                          0,1 V                             ±(2,5% w.m. + 8 digits)    ±(2% m.v. + 5 digits)
	frequency range: 50...400Hz.
	DC voltage measurement
	Range                      Resolution             Accuracy
	400,0 Ω                    0,1 Ω                      ±(1,0% m.v. + 4 digits)
	4,000 k Ω                 0,001kΩ                 ±(1,5% m.v. + 2 digits)
	40,00 k Ω                 0,01 kΩ                  ±(1,5% m.v. + 2 digits)
	400,0 k Ω                 0,1 kΩ                    ±(1,5% m.v. + 2 digits)
	4,000 M Ω               0,001 MΩ              ±(2,5% m.v. + 3 digits)
	40,00 M Ω              0,01 MΩ                  ±(3,5% m.v. + 5 digits)
	Capacitance measurement (CMP-401 only): Ampe kìm đo dòng CMP_400, CMP-401
	Range                       Resolution                  Accuracy
	40,00 nF                    0,01 nF                      ±(4% m.v. + 20 digits)
	400,0 nF                    0,1 nF                        ±(3% m.v. + 5 digits)
	4,000 μF                    0,001 μF                    ±(3% m.v. + 5 digits)
	40,00 μF                    0,01 μF                      ±(3% m.v. + 5 digits)
	100,0 μF                    0,1 μF                         ±(4% m.v. + 10 digits)
	Electric security:
	- measurement category  CAT III 600V acc. to EN 61010-1:2004
	- protection class acc. to EN 60529 IP40
	Other technical data:
	- power supply  9V battery type 6LR61
	- display 4000 counts, backlit LCD
	- continuity test I<0,5mA, sound signal for R<50Ω
	- diode test  I=0,3mA, U =1,5V DC 0
	- over range indication   0L displayed
	- sampling rate  2 times per second
	- input impedance 10MΩ (V DC and V AC)
	- clamp size opening 30mm (1,2”)
	- auto power OFF  approx. 30 min.
	- dimensions 197 x 70 x 40 mm
	- weight 183 g
	- accordance with following standards  EN 61010-1:2004
	EN 61010-2-032
	- quality standard  ISO 9001
	Rated operational conditions:
	- operating temperature 0...+40°C
	- storage temperature -20...+60°C
	- operating humidity max 80% up to 31°C
	decreasing linearly to 50% at 40°C
	- operating altitude max 2000 m